- Do not use Hylane G-F 20 if the packaging is open or damaged.
- The contents of the syringe must be used immediately after opening the packaging.
- Aspirate the synovial fluid or any effusion before each injection of Hylane G-F 20.
- Inject Synvisc at room temperature.
- To remove the syringe from the blister (or tray), hold it by the barrel without touching the plunger rod.
- Inject Synvisc using strict aseptic techniques, paying particular attention when removing the cap from the tip of the syringe.
- Unscrew the grey cap at the tip of the syringe before removing it to minimise product leakage.
- Use a needle of appropriate gauge.
- Use a needle of adequate length, depending on the joint
Synvisc-One: 18 to 20 gauge.
- To ensure a tight seal and prevent leakage during administration, firmly attach the needle to the Luer lock collar of the syringe.
- Do not overtighten or apply excessive force when attaching the needle or removing its sheath, as this may break the tip of the syringe.
- Inject only into the synovial space, performing the procedure, if necessary, under fluoroscopic guidance, particularly when treating hip and shoulder joints.
- The contents of the syringe are for single use only. As indicated in the dosage recommendations, inject the entire volume of the syringe (2 ml for Synvisc and 6 ml for Synvisc-One). Discard any remaining unused Synvisc/Synvisc-One product.
- When working under fluoroscopic control, an ionic or non-ionic contrast medium may be used. Do not use more than 1 ml of contrast medium per 2 ml of Hylane G-F 20.
- Do not resterilise Hylane G-F 20.